HVAC Pressure Transmitters

Sensors/Pressure/HVAC Pressure Transmitters 
Viewing Page 1 of 3 (25 results)
Diff Press Transmitter 0-10in w/ Display

Diff Press Transmitter 0-10in w/ Display

Item #: A/DLP-010-W-U-D-A-3
Brand: ACI
141075

Diff Press Transmitter 0-10in w/ Display 0-1in, 0-2in, 0-5in, 0-10in w.c. (uni/bi-directional); includes pitot tube for duct mounting and din rail clip for panel mounting; 0.5% accuracy; Field selectable output - 4-20 mA (default), 0-5 VDC, 0-10 VDC
Diff Press Transmitter 0-10in w/o LCD

Diff Press Transmitter 0-10in w/o LCD

Item #: A/DLP-010-W-U-N-A-0
Brand: ACI
140774

Diff Press Transmitter 0-10in w/o LCD 0-1in, 0-2in, 0-5in, 0-10in w.c. (uni/bi-directional); No display; Transmitter only, does not includes pitot tube for duct mounting or din rail clip for panel mounting; 0.5% accuracy; Field selectable output - 4-20 mA (default), 0-5 VDC, 0-10 VDC
Diff Press Transmitter 0-10in w/o LCD

Diff Press Transmitter 0-10in w/o LCD

Item #: A/DLP-010-W-U-N-A-3
Brand: ACI
141074

Diff Press Transmitter 0-10in w/o LCD 0-1in, 0-2in, 0-5in, 0-10in w.c. (uni/bi-directional); No display; includes pitot tube for duct mounting and din rail clip for panel mounting; 0.5% accuracy; Field selectable output - 4-20 mA (default), 0-5 VDC, 0-10 VDC
WET TO WET, 0-300PSI, 20', LCD

WET TO WET, 0-300PSI, 20', LCD

Item #: A/WPR2-300-20-LCD
Brand: ACI
138106

WET TO WET, 0-300PSI, 20', LCD
WET TO WET, 0-100PSI, 20', LCD

WET TO WET, 0-100PSI, 20', LCD

Item #: A/WPR2-100-20-LCD
Brand: ACI
138105

WET TO WET, 0-100PSI, 20', LCD Nema 4X
WET TO WET, 0-100PSI, 20'

WET TO WET, 0-100PSI, 20'

Item #: A/WPR2-100-20
Brand: ACI
138189

WET TO WET, 0-100PSI, 20'
Diff Press Transmitter 0-1in w/ Display

Diff Press Transmitter 0-1in w/ Display

Item #: A/DLP-001-W-U-D-A-3
Brand: ACI
141073

Diff Press Transmitter 0-1in w/ Display 0-0.1in, 0-0.2in, 0-0.5in, 0-1in w.c. (uni/bi-directional); includes pitot tube for duct mounting and din rail clip for panel mounting; 0.5% accuracy; Field selectable output - 4-20 mA (default), 0-5 VDC, 0-10 VDC
Diff Press Transmitter 0-5in w/o Display

Diff Press Transmitter 0-5in w/o Display

Item #: A/DLP-005-W-U-N-B-0-A-0P-S
Brand: ACI
147411

Diff Press Transmitter 0-5in w/o Display 0-5in w.c. unidirectional; No display; Transmitter only, does not includes pitot tube for duct mounting or din rail clip for panel mounting; 0.25% accuracy; 4-20 mA output
Diff Press Transmitter 0-1in w/o Display

Diff Press Transmitter 0-1in w/o Display

Item #: A/DLP-001-W-U-N-A-0
Brand: ACI
140769

Diff Press Transmitter 0-1in w/o Display 0-0.1in, 0-0.2in, 0-0.5in, 0-1in w.c. (uni/bi-directional); Transmitter only, does not includes pitot tube for duct mounting or din rail clip for panel mounting; 0.5% accuracy; Field selectable output - 4-20 mA (default), 0-5 VDC, 0-10 VDC
Diff Press Transmitter 0-1in w/o Display

Diff Press Transmitter 0-1in w/o Display

Item #: A/DLP-001-W-U-N-A-3
Brand: ACI
141072

Diff Press Transmitter 0-1in w/o Display 0-0.1in, 0-0.2in, 0-0.5in, 0-1in w.c. (uni/bi-directional); includes pitot tube for duct mounting and din rail clip for panel mounting; 0.5% accuracy; Field selectable output - 4-20 mA (default), 0-5 VDC, 0-10 VDC