Every BAS technician has the basics, but sometimes it’s the less-obvious tools that can save the most time on a jobsite. In this guide, we go beyond the multimeter and break down practical tools for troubleshooting BACnet and RS-485 networks, simulating inputs and outputs, verifying BAS values, testing IP networks, and isolating problems faster.
Why it matters: Whether you’re building your first BAS toolbox or looking for a few additions to your truck, these are the tools and troubleshooting kits worth having before you actually need them.
Beyond the Multimeter: Uncommon Tools Every Controls Technician Should Have
Every technician knows the basics: a good multimeter, screwdrivers, wire strippers, hand tools, and a laptop. But once you start commissioning and troubleshooting real building automation systems, another category of tools can make your life a whole lot easier.
Jump to a Section
Each section below can be opened and collapsed so you can quickly get to the tools you need.
What’s in Your BAS Toolbox?
We put together our list—but we know every System Integrator has a few go-to tools of their own. What did we miss? Share the tools, testers, adapters, or jobsite lifesavers you think belong on the list.
Tell Us What We MissedNetworking & BACnet Tools
Modern controls technicians are part HVAC technician, part electrician, and increasingly, part network technician.
USB-to-RS485 Adapter
A USB-to-RS485 adapter allows a laptop to connect directly to an RS-485 network.
Depending on the software being used, it can be extremely useful when troubleshooting:
- BACnet MS/TP
- Modbus RTU
- Device addressing
- Communication problems
- Individual field devices
It gives you another way to determine whether the controller, network, or BAS front end is causing the problem.
BACnet Discovery & Troubleshooting Software
An independent BACnet troubleshooting utility on your laptop can help determine whether devices are visible on the network without relying entirely on the BAS front end.
- BACnet device discovery
- Device IDs
- IP addresses
- BACnet objects
- Duplicate device IDs
- Communication issues
A Second USB Ethernet Adapter
This may be one of the cheapest productivity upgrades for a BAS technician.
It can also make troubleshooting IP addresses, routing, DHCP, and subnet problems much easier.
Small Unmanaged Ethernet Switch
A small Ethernet switch can be extremely handy for creating a temporary network or connecting several devices during commissioning.
It can also help isolate BAS equipment from the customer's larger network while troubleshooting.
Travel Router
A small travel router lets you create a temporary private network for commissioning or bench testing, especially before the customer's permanent network is available.
Ethernet Cable Tester
Do not spend an hour troubleshooting BACnet/IP when the problem is actually the cable.
- Opens
- Shorts
- Miswired pairs
- Damaged conductors
Add known-good patch cables, Ethernet couplers, an RJ45 crimper, and spare connectors for a simple network repair kit.
Build an “RS-485 Bag”
Consider making a small pouch labeled RS-485 standard equipment.
- 120-ohm resistors
- USB-to-RS485 adapter
- Small screwdriver
- Short pieces of shielded twisted-pair cable
- Wire connectors or Wagos
- Alligator jumpers
- Spare terminal blocks
- RS-485 troubleshooting cheat sheet
When a BACnet MS/TP or Modbus trunk goes sideways, everything you need is already in one place.
Do Not Forget the 120-Ohm Resistors
A couple of 120-ohm resistors take up almost no room in a toolbox, but can be invaluable when troubleshooting RS-485 communication problems and verifying proper end-of-line termination.
Tools for Simulating Inputs & Outputs
Some of the most useful BAS troubleshooting tools let you simulate what the controller should be seeing or sending. Instead of guessing, substitute a known signal and observe what happens.
Resistance Decade Box
A resistance decade box is one of the best troubleshooting tools many new BAS technicians have never used.
Imagine a controller has a 10K thermistor connected to an analog input, but the BAS is displaying 87°F when the space clearly is not 87°F.
Disconnect the sensor and substitute a known resistance. If the controller now displays the expected temperature, you have eliminated a large portion of the system from suspicion.
A precision resistor kit can accomplish the same basic idea, but a decade box makes changing resistance values much easier.
0–10 V & 4–20 mA Signal Generators
Signal generators turn troubleshooting into a controlled experiment.
Disconnect the controller's analog output and connect a 0–10 V signal generator directly to the VFD. Command 5 V and observe the response.
The same technique can be used with:
- Control valves
- Damper actuators
- VFDs
- Pressure sensors
- Flow transmitters
- Humidity transmitters
- Industrial instrumentation
Tools for Verifying What the BAS Is Telling You
Just because a value appears on the BAS does not mean it is correct. Independent measurements are critical.
Differential Pressure Manometer
If the BAS says duct static pressure is 1.7 inches w.c., how do you know that is actually true? Measure it.
- Duct static pressure
- Building pressure
- Filter differential pressure
- Airflow pressure relationships
- Pressure sensor calibration
Sometimes the BAS is controlling perfectly based on bad information from a sensor.
Temperature Probe
Use an independent temperature probe to compare actual temperature against space sensors, discharge-air sensors, return-air sensors, outside-air sensors, pipe sensors, and BAS values.
IR Thermometer
An infrared thermometer is not a replacement for a proper temperature probe, but it is a great quick diagnostic tool.
- Hot-water pipes
- Chilled-water pipes
- Coils
- Discharge-air temperatures
- Equipment surfaces
Better Multimeter Accessories
Sometimes you do not need another meter. You just need better ways to use the one you already have.
Useful Add-Ons
- Alligator-clip leads
- Needle probes
- Back-probe leads
- Mini jumper leads
- Low-current DC clamp capability
Alligator clips let you monitor a measurement without holding two probes in place. Back probes can let you measure a signal without disconnecting the circuit. Jumper leads can help temporarily simulate contacts, commons, and other signals during commissioning.
Create a “Known-Good” Box
One of the best troubleshooting kits a technician can build is not something you buy preassembled. It is a collection of known-good components.
What to Keep Inside
- 10K temperature sensor
- 0–10 V device
- 4–20 mA device
- Relay
- BACnet MS/TP device
- BACnet/IP device
- 24 VAC transformer
- 24 VDC power supply
- Known-good Ethernet cable
Troubleshooting frequently comes down to substitution and isolation. Every successful substitution reduces the number of possible causes.
The “Why Didn’t I Bring That?” Tools
Not everything needs to be technical. Some of the most appreciated tools in a BAS technician's truck are the ones that solve annoying jobsite problems.
Carry a Small BAS “Get Me Out of Trouble” Kit
Every technician eventually develops a collection of parts that have saved a job. A new technician can get ahead of that process.
Useful Spares
- Fuses
- Terminal jumpers
- Wire connectors
- Short pieces of control wire
- 120-ohm resistors
- Spare terminal blocks
- Ethernet couplers
- Short patch cables
- Small 24 VAC transformer
- 24 VDC power supply
- Test leads
- Common resistors
The Cheapest Tool on the List: A BAS Field Notebook
One of the most useful tools might cost less than $10. Carry a dedicated BAS field notebook—and turn the back section into your personal troubleshooting reference.
Don’t Build a Toolbox. Build Troubleshooting Kits.
When outfitting a new BAS technician, handing them a list of 50 tools is not necessarily the best approach. Organize the truck around five troubleshooting kits instead.
The Best BAS Technicians Know What to Test Next
The best BAS technicians are not necessarily the people carrying the most tools. They are the technicians who know which tool to grab next—and what that test will prove.
What’s in Your BAS Toolbox?
Think we missed something? We want to hear from the System Integrators and controls technicians doing this work every day. Share the tools you would add to the list.
Add Your Tool to the List